Quick Inspection of Secondary Air Valves
Information on the product
Noisy secondary air pump? Why do speed fluctuations occur on cold engines? What is the cause of the diagnostic trouble code P0410 and P0411? Find out why you should check the actuating electric switchover valve and the secondary air valve here.
The following customer complaints can occur during the cold-running phase in vehicles that have a secondary air system:
- secondary air pump (SLP) makes noises
- SLP does not work
- repeated failure of the SLP after a brief running period
- variation in revs when the engine is cold Possible OBD error codes are: P0410; P0411
The trigger for this damage remains in the vehicle and can lead to the recurrent failure of the secondary air pump. When replacing the secondary air pump, the electrical reversing valve and the secondary air valve must be inspected for leaks as a basic principle.
The secondary air valve can be quickly inspected in an easy way:
- Loosen the connecting hose on the secondary air non-return valve leading to the secondary air pump. See inspection point “P” on the graphic overleaf
- If there are deposits on this side of the valve (finger test, see Fig. 1), the nonreturn valve is leaky and must be replaced. In that case the secondary air pump may already have been damaged.
- Inspect the secondary air pump and replace it if necessary.
In almost all cases this damage is caused by exhaust gas conden sate in the second-ary air pump. In repairs, often only the secondary air pump is replaced.
![]() |
NOTE However, the actual cause of the damage is not in the secondary air pump. |
01 secondary air pump
02 electrical reversing valve (EUV)
03 switch-off non-return valve (approx. 1995 )
04 secondary-air switch-off valve (approx. 1993 1997)
05 secondary-air non return valve (approx. 1993 1997)
P inspection point for quick inspection
Secondary air valves are an integral part of the secondary air system. They are fitted between the secondary air pump (1) and exhaust manifold. They prevent pressure peaks in the exhaust flow from damaging the secondary air system and exhaust gas or condensate from entering the secondary air pump. There are different designs of secondary air valves:
Switch-off non-return valves (3) are generally vacuum-operated valves. Later designs (from approx. 1998 ) are opened by the pressure of the secondary air. This does away with pneumatic control by an electrical reversing valve (2). Secondary-air non-return valves (5) open as a result of the pressure of the secondary airflow.