jumpToMain

Cavitation

Water pumps can sustain holes due to cavitation on the housing, causing them to leak. In certain circumstances, metal pump impellers are sufficiently weakened by cavitation that they break. The cavitation is often only detected once the water pump has been dismantled.

Cavitation is the result of:

  • Maintenance errors
  • Improper operating conditions
  • Cooling system malfunction
  • Incorrect cooling liquid


Cavitation may also indicate that the water pump was not installed 
with due care and attention.

Pump housing damaged by cavitation
Pump housing damaged by cavitation

When liquids reach their boiling point, small vapour bubbles are formed that suddenly collapse (implode). When the bubbles disintegrate, a micro jet is characteristically formed in the middle of the bubble. The liquid is sharply accelerated in the micro jet. Pressure peaks of up to 10,000 bar and speeds of up to 400 km/h impact the component surface in individual places. 

This causes small metal particles to be torn from the component surface by mechanical means. If the cavitation always occurs at the same location, increasingly deep holes or cavities will be formed over time.

Bubble formation and bubble disintegration
Bubble formation and bubble disintegration

Vapour bubbles are formed when the boiling point of a liquid is reached. This is dependent on three parameters:

  1. The boiling point of the liquid itself.
  2. The pressure in the liquid.
  3. The temperature of the liquid.


These three parameters influence one another. Please see below for the causes that govern the way in which the boiling point can be reached in an engine cooling system. The attainment of the boiling point and the occurrence of cavitation are often due to multiple causes at the same time.

  • Leaking cooling system.
  • Faulty or incorrect radiator filler cap – incorrect opening pressure of the pressure relief valve.
  • Insufficient operating temperature of the engine – engine operation without thermostat, or thermostat with insufficient opening temperature.
  • Engine operation in high mountain regions – the low ambient pressure also affects the operating pressure in the cooling system.
  • Local low-pressure zones on components caused by oscillation of components.
  • Local low-pressure zones due to fast movements of components in liquids, particularly in pump impellers and propellers.
  • High flow velocity of liquids combined with a sharp change in the direction of flow or with flow reversal. If the flow velocity is so high that the static pressure falls below the evaporation pressure of the liquid, this leads to the formation of vapour bubbles.
  • Use of normal water without the addition of coolant agent.
  • Unsuitable cooling liquid (insufficient coolant agent concentration, ageing cooling liquid).

Due to overstressing of the engine or malfunctions in the combustion process, more heat is generated than stated in the specification.
Poor functioning of the cooling system, for example due to a lack of coolant liquid, blocked radiator, pollution on the outer face of the radiator, defective viscous couplings, worn drive belt, failure of the electrical cooling fan, etc.